E01 – Connection error occurred between the control panel and the indoor unit

E02 – the control panel has failed to connect

E03 – Connection error occurred between the indoor unit and the control panel

E04 – Connection error external / internal block

E06 – there is no power to the indoor unit, there was a communication error between the units, a connection error or a malfunction of the outdoor or indoor unit

E07 – thermal sensor failure SW30-2, communication error occurred between units

E08 – internal block addresses are duplicated

E09 – the control panel settings are violated, the control panel malfunction

E10 – a failure of the internal

E12 – Connection error occurred in outdoor unit or internal / outdoor unit connection

E15 – an error occurred on the internal, power supply, interconnection, power supply

E16 – an error has occurred in the power of the indoor units, the external unit card is faulty or the setting error

E18 – the console is not powered, the internal unit board is faulty or an error in the connection of the control panel

E19 – Connection error occurred between indoor and outdoor unit, the board is faulty

E20 -separate the cable between lines acording to automatic addres setup method in “Address setup”

E23 – An error has occurred connecting the outdoor units, this model has only one external unit with one refrigerant circuit

E25 – the address of the outdoor unit is not assigned

E26 – An error occurred connecting the outdoor units

E28 -the sequence of outdoor units is broken

E31 – card malfunction, interference / interference, card connection error in outdoor unit

F01 – TCJ sensor connection is incorrect, sensor is defective, internal card is faulty

F02 – TC2 sensor connection incorrect, sensor fault, internal board faulty

F03- connection of TC1 sensor is wrong, sensor is defective, internal card is faulty

F04- connection of sensor TD1 is incorrect, sensor malfunction, internal board is defective

F05- TD2 sensor error occurred

F06- TE1 sensor connection is wrong, sensor is defective, internal card is faulty

F07- TL sensor connection incorrect, sensor fault, internal board faulty

F08- TO sensor connection wrong, internal circuit board faulty, sensor defective

F10- TA sensor connection is incorrect, sensor fault, internal board is faulty

F12- the connection of the TC1 sensor is incorrect, the internal board is malfunctioning,

Sensor defective

F13 – IGBT power module sensor error occurred

F15 – there was an error installing the sensors TE1 and TL, sensor failure, the internal board is faulty

F16- low / high resistance sensors Ps, connection error Pd, card malfunction, malfunction

F23 – error occurred Ps / Pd sensors, error 4-way valve, circuit board SV4, compressor

F24 – error occurred in the board or high pressure Pd sensor

F29 – EEPROM (internal non-volatile memory) error of the indoor board

F31- An electrical power error has occurred, an error of the external unit board or power supply interference

H01 – compressor error, supply voltage lower / above normal, card error, overload

H02 – compressor error, supply voltage lower / above normal, phasing error, card error, overload

H03 – board error occurred, current sensor

H04 – error of the compressor, SV5, SV4 circuit, refrigerant, 4-way valve

H06 – fixation by the low pressure sensor Ps of pressure 0.02 MPa

H07 – low oil level protection

H08 – oil level temperature sensor

H14 – error occurred on 2 compressors

H16 – oil level sensor fault, overcurrent relay fault, magnetic switch

L03 – an address error occurred in the outdoor unit

L04 – an error occurred on the address line

L05 – an internal block priority error occurred.

L06 – Error of priority reading of outdoor unit and indoor unit

L07 – An error occurred in the address of the external block

L08- An address error occurred on the external

L09 – An error occurred in the power settings of indoor units

L10 – There was an error installing the external block model

L17

L18

L20 – Network adapter error occurred

L28 – an error occurred in connecting external units – maximum in one system four blocks, an error in the connection between external blocks, the board is faulty

L29 – UART error occurred, the settings for the external block are violated

L30 – external / internal board error occurred

L31 – Internal board error occurred

P01 – fan motor is blocked, fan motor power failure

P03 – insufficient refrigerant, 4-way valve error, inverter converter, TD1 sensor, SV4 circuit, SV5

P04 – insufficient refrigerant, 4-way valve error, inverter converter, TD1 sensor, SV2 circuit, SV4, SV5, fan motor is blocked, motor fan is interrupted, circuit is refilled, external unit board is faulty

P05 –

P07 – an external fan error occurred, the supply voltage is above / below normal, the radiator error of the power module cooling, the error of the temperature sensor of the power module

P10- there was an error of the drain pump, the indoor unit board

Float switch

P12- There is an internal fan motor fan error

P13 – Error occurred when returning refrigerant liquid

P15 – the refrigerant has leaked

P17 – the TD2 sensor error has occurred

P19 – 4-way valve error occurred

P20 – high pressure protection

P22 – the fan is defective, the board is faulty

P26 – Compressor short circuit protected

P29 – Compressor wedges

P31 – An error has occurred in the indoor units

C05 – An error occurred while sending controller signals

C06 – An error occurred while receiving controller signals

C12 – Interface error occurred

P30 – duplicated addresses

00-0C – an internal air temperature sensor error or an indoor unit board error has occurred

00-0d – the control card or the temperature sensor of the radiator has failed

00-11 – Fan board or fan malfunction

00-12 – Control board requires replacement

01-04 – fuses burned on board, interconnection wrong, board burned down

01-05 – Inverter board error occurred

02-14 – Inverter current overload

02-16 – there was a shortage between compressor windings

02-17 – current sensor error occurred

02-18 – an error occurred in the sensors of the P.C. board, the temperature

02-19 – TD temperature sensor error occurred, P.C. Fees

02-1A – the fan of the external unit has occurred – current overload, blocked, the board or the engine burnt out

02-1b- Condenser temperature sensor or board is defective

02-1C – the compressor was not started for 20 seconds

03-07 – Inverter board error occurred, the refrigerant is not sufficient

03-1d – compressor fault

03-1E – error occurred in the suction pipe sensor TD, lack of refrigerant

03-1F – compressor does not work due to power supply, refrigeration circuit overload

03-08 – 4-way valve defective

Leave a Comment

Your email address will not be published. Required fields are marked *